NASA NTRS · 19920030775
Low capacity Linde-Hampson nitrogen liquefier
Abstract
A closed-cycle Linde-Hampson nitrogen liquefier was developed incorporating a new, non-clogging, demand flow Joule-Thomson nozzle. The flow area of the nozzle, a tapered annular orifice, is regulated by a very rugged load-sensitive differential thermal expansion scheme and by a manually adjustable micrometer mechanism. Labyrinth flow spoilers within the orifice provide turbulent voids which break up and clear contaminants from the flow. The system's four-stage compressor features sealed, oil-free compression spaces and a very compact nested piston configuration with a minimum of moving parts and drive complexity. The drive mechanism is a rolling Scotch yoke which minimizes piston side forces and seal wear for prolonged operating life. The closed-cycled system is controlled by an innovative load-responsive electronic feedback circuit which further reduces wear and input power.
Keep this discovery
Explore connections, maps & timelines
Hedegard, K., Atkins, E., Walker, G.. 1990-01-01. Low capacity Linde-Hampson nitrogen liquefier. https://ntrs.nasa.gov/citations/19920030775