Search NASASearch

NASA NTRS · 19920068785

Thermal-structural panel buckling tests

Abstract

A titanium-matrix-composite (TMC) hat-stiffened panel of 61 cm sq area and 3.175 cm thick was nondestructively tested to 649 C to examine its buckling characteristics. Compressive loads were applied to the panel in a 978.6 kN uniaxial load frame system. High-temperature testing was performed using quartz lamp heating. A single-strain-age force/stiffness buckling prediction technique was developed to predict panel buckling loads. For the monolithic panel, these test predictions correlated within 10 percent with a finite-element buckling analyses performed elsewhere. Comparisons between force/stiffness predictions and analyses for the TMC panel are in progress.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thompson, Randolph C., Richards, W. L.. 1991-01-01. Thermal-structural panel buckling tests. https://ntrs.nasa.gov/citations/19920068785