Strain Gauges Mounted To Retain Calibration

Abstract

Silicon-based semiconductor strain gauges mounted in such way they retain original calibration for several years instead of few months. Improvement effected by bonding gauges to ceramic substrates with glasses instead of epoxies as adhesives.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Butler, Barry L.. 1993-03-01. Strain Gauges Mounted To Retain Calibration. https://ntrs.nasa.gov/citations/19930000175