Search NASA⌕ Search

NASA NTRS · 19940000628

Using Si Diodes To Detect H2 Liquid/Vapor Interfaces

Abstract

Commercially available silicon-diode temperature sensors used to detect interfaces between hydrogen liquid and hydrogen vapor at steady-state saturation conditions. Sensors mounted at short intervals along rod to form rake-like array. Array inserted in tank with rod oriented vertically, where it senses level of liquid hydrogen to resolution equal to interval between sensors. Basic idea to measure voltage across sensor while supplying small electric current that heats sensor. Because vapor cools sensor less effectively than liquid does, sensor's steady-state temperature greater when sensor surrounded by vapor than when immersed in liquid. Voltage output decreases as temperature increases for silicon diodes. Thus, temperature (voltage) reading used to determine whether liquid level above or below sensor.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dempsey, Paula Jean, Fabik, Richard. 1994-11-01. Using Si Diodes To Detect H2 Liquid/Vapor Interfaces. https://ntrs.nasa.gov/citations/19940000628

Cite the original work for its findings. Save a collection to share your selection of sources.