Search NASA⌕ Search

NASA NTRS · 19940016613

STRV RADMON: An integrated high-energy particle detector

Abstract

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Buehler, Martin, Soli, George, Blaes, Brent, Tardio, Gemma. 1993-01-01. STRV RADMON: An integrated high-energy particle detector. https://ntrs.nasa.gov/citations/19940016613

Cite the original work for its findings. Save a collection to share your selection of sources.