Search NASA⌕ Search

NASA NTRS · 19940023916

Mechanical flexible joint design document

Abstract

The purpose of this report is to document the status of the Mechanical Flexible Joint (MFJ) Design Subtask with the intent of halting work on the design. Recommendations for future work is included in the case that the task is to be resumed. The MFJ is designed to eliminate two failure points from the current flex joint configuration, the inner 'tripod configuration' and the outer containment jacket. The MFJ will also be designed to flex 13.5 degrees and have three degrees of freedom. By having three degrees of freedom, the MFJ will allow the Low Pressure Fuel Duct to twist and remove the necessity to angulate the full 11 degrees currently required. The current flex joints are very labor intensive and very costly and a simple alternative is being sought. The MFJ is designed with a greater angular displacement, with three degrees of freedom, to reside in the same overall envelope, to meet weight constraints of the current bellows, to be compatible with cryogenic fuel and oxidizers, and also to be man-rated.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daily, Vic. 1993-10-22. Mechanical flexible joint design document. https://searchnasa.com/record/nasa%3A19940023916/mechanical-flexible-joint-design-document