Unique passive diagnostic for slapper detonators
Abstract
The objective of this study was to find a material and configuration that could reliably detect the proper functioning of a slapper (non-explosive) detonator. Because of the small size of the slapper geometry (on the order of a 15 mils), most diagnostic techniques are not suitable. This program has the additional requirements that the device would be used on centrifuge so that it could not use any electrical power or output signals. This required that the diagnostic be completely passive. The paper describes the three facets of the development effort: complete characterization of the slapper using VISAR measurements, selection of the diagnostic material and configuration, and testing of the prototype designs. The VISAR testing required that use of a special optical probe to allow the laser light to reach both bridges of the dual-slapper detonator. Results are given in the form of flyer velocity as a function of the initiating charge voltage level. The selected diagnostic design functions in a manner similar to a dent block except that the impact of the Kapton disk from a properly-functioning slapper causes a fracture pattern. A quick visual inspection is all that is needed to determine if the flyer velocity exceeded the threshold value. Sub-threshold velocities produce a substantially different appearance.