Search NASA⌕ Search

NASA NTRS · 19980236755

Double-Edge Molecular Technique for Doppler Lidar Wind Measurement

Abstract

The double-edge lidar technique for measuring the wind using molecular backscatter is described. Two high spectral resolution edge filters are located in the wings of the Rayleigh-Brillouin profile. This doubles the signal change per unit Doppler shift, the sensitivity, and gives nearly a factor of two improvement in measurement accuracy. The use of a crossover region is described where the sensitivity of a molecular and aerosol-based measurement are equal. This desensitizes the molecular measurement to the effects of aerosol scattering over a frequency range of +/- 100 m/s. We give methods for correcting for short-term frequency jitter and drift using a laser reference frequency measurement and methods for long-term frequency correction using a servo control system. The effects of Rayleigh-Brillouin scattering on the measurement are shown to be significant and are included in the analysis. Simulations for a conical scanning satellite-based lidar at 355 nm show an accuracy of 2-3 m/s for altitudes of 2 to 15 km for a 1 km vertical resolution, a satellite altitude of 400 km and a 200 km x 200 km spatial resolution. Results of ground based wind measurements are presented.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Flesia, Cristina, Korb, C. Laurence. 1998-07-01. Double-Edge Molecular Technique for Doppler Lidar Wind Measurement. https://ntrs.nasa.gov/citations/19980236755