Search NASASearch

NASA NTRS · 19990040477

Cable Bundle Wire Derating

Abstract

The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 degree C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire (2) bundle of 15 or more wires (3) 70 C environment (4) vacuum of 10(exp -5) torr or less To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lundquist, Ray A., Leidecker, Henning. 1999-02-01. Cable Bundle Wire Derating. https://ntrs.nasa.gov/citations/19990040477