Search NASAโŒ• Search

NASA NTRS ยท 20000063497

Environmental Test Screening Procedure

Abstract

This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zeidler, Janet. 2000-03-30. Environmental Test Screening Procedure. https://ntrs.nasa.gov/citations/20000063497

Cite the original work for its findings. Save a collection to share your selection of sources.