NASA NTRS · 20000068484
International Space Station United States Oxygen Generator Development Testing
Abstract
A life test of a liquid anode feed oxygen generator assembly (OGA) using SPE(R) (United Technologies Corporation, Hamilton Sundstrand Division) membrane technology was terminated in June of 1999. In the total 15,658 hours of operation at MSFC since delivery in 1995, the OGA has produced 2,103 kilograms (kg) (4,632 pounds mass (lbm)) of oxygen, and 263 kg (579 lbm) of hydrogen. Evaluation of cell stack characteristics and oxygen and hydrogen hydrophilic/hydrophobic membrane separators will be discussed.
Keep this discovery
Explore connections, maps & timelines
Erickson, Robert J., Mason, Richard K.. 2000-01-01. International Space Station United States Oxygen Generator Development Testing. https://ntrs.nasa.gov/citations/20000068484