NASA NTRS ยท 20000068919
Computer Tomography Analysis of Fastrac Composite Thrust Chamber Assemblies
Abstract
Computed tomography (CT) inspection has been integrated into the production process for NASA's Fastrac composite thrust chamber assemblies (TCAs). CT has been proven to be uniquely qualified to detect the known critical flaw for these nozzles, liner cracks that are adjacent to debonds between the liner and overwrap. CT is also being used as a process monitoring tool through analysis of low density indications in the nozzle overwraps. 3d reconstruction of CT images to produce models of flawed areas is being used to give program engineers better insight into the location and nature of nozzle flaws.
Keep this discovery
Explore connections, maps & timelines
Beshears, Ronald D.. 2000-04-20. Computer Tomography Analysis of Fastrac Composite Thrust Chamber Assemblies. https://ntrs.nasa.gov/citations/20000068919