Abstract
As a result of federal and state requirements, historical critical cleaning and verification solvents such as Freon 113, Freon TMC, and Trichloroethylene (TCE) are either highly regulated or no longer 0 C available. Interim replacements such as HCFC 225 have been qualified, however toxicity and future phase-out regulations necessitate long term solutions. The scope of this project was to qualify a safe and environmentally compliant LOX surface verification alternative to Freon 113, TCE and HCFC 225. The main effort was focused on initiating the evaluation and qualification of HCFC 225G as an alternate LOX verification solvent. The project was scoped in FY 99/00 to perform LOX compatibility, cleaning efficiency and qualification on flight hardware.
Keep this discovery
Explore connections, maps & timelines
Melton, Donald M., McCool, A.. 2000-01-01. Critical Surface Cleaning and Verification Alternatives. https://ntrs.nasa.gov/citations/20000094841
Cite the original work for its findings. Save a collection to share your selection of sources.