Abstract

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

Keep this discovery

BibTeXRIS

M R Shavers, P B Saganti, J Miller, F A Cucinotta. 2003-12-01. Introduction to Radiation Issues for International Space Station Extravehicular Activities: Chapter 1. https://ntrs.nasa.gov/citations/20040065979

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related discoveries

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Spacecraft thermal control coatings: Comparison between flight results obtained on LDEF and MIR

The COMES experiment was installed outside of the MIR space station during an extravehicular activity. The experiment was exposed to vacuum, atomic oxygen, and ultraviolet radiation (UV) for 1.1 years. Due to a lack of knowledge about the spacecrafts actual attitude, there is a large uncertainty in the atomic oxygen fluence and the UV dose that was experienced by COMES. Additionally, contaminants of many different origins were observed on the COMES samples.

Jean-Claude Guillaumon

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield