Search NASA⌕ Search

NASA NTRS · 20040088810

Development of an automated diode-laser-based multicomponent gas sensor

Abstract

The implementation and application of a portable fiber-coupled trace-gas sensor for the detection of several trace gases, including CO2, CH4, and H2CO, are reported. This particular sensor is based on a cw fiber-amplified near-infrared (distributed Bragg reflector) diode laser and an external cavity diode laser that are frequency converted in a periodically poled lithium niobate crystal to the mid-IR spectroscopic fingerprint region (3.3-4.4 micrometers). A continuous absorption spectrum of CH4 and H2CO from 3.37 to 3.10 micrometers with a spectral resolution of 40 MHz (approximately 0.0013 cm-1) demonstrated the spectral performance that can be achieved by means of automated wavelength tuning and phase matching with stepper motor control. Autonomous long-term detection of ambient CO2 and CH4 over a 3- and 7-day period was also demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richter, D., Lancaster, D. G., Tittel, F. K.. 2000-08-20. Development of an automated diode-laser-based multicomponent gas sensor. https://ntrs.nasa.gov/citations/20040088810

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Antibody binding in altered gravity: implications for immunosorbent assay during space flight

A single antibody-incubation step of an indirect, enzyme-linked immunosorbent assay (ELISA) was performed during microgravity, Martian gravity (0.38 G) and hypergravity (1.8 G) phases of parabolic flight, onboard the NASA KC-135 aircraft. Antibody-antigen binding occurred within 15 seconds; the level of binding did not differ between microgravity, Martian gravity and 1 G (Earth's gravity) conditions. During hypergravity and 1 G, antibody binding was directly proportional to the fluid volume (per microtiter well) used for incubation; this pattern was not observed during microgravity. These effects in microgravity may be due to "fluid spread" within the chamber (observed during microgravity with digital photography), leading to greater fluid-surface contact and subsequently antibody-antigen contact. In summary, these results demonstrate that: i) ELISA antibody-incubation and washing steps can be successfully performed by human operators during microgravity, Martian gravity and hypergravity; ii) there is no significant difference in antibody binding between microgravity, Martian gravity and 1 G conditions; and iii) a smaller fluid volume/well (and therefore less antibody) was required for a given level of binding during microgravity. These conclusions indicate that reduced gravity would not present a barrier to successful operation of immunosorbent assays during spaceflight.

NASA Discipline Environmental Health↗

Patent foramen ovale and paradoxical systemic embolism: a bibliographic review

A patent foramen ovale (PFO) has been reported to be an important risk factor for cardioembolic cerebrovascular accidents through paradoxical systemic embolization, and it provides one potential mechanism for the paradoxical systemic embolization of venous gas bubbles produced after altitude or hyperbaric decompressions. Here, we present in a single document a summary of the original findings and views from authors in this field. It is a comprehensive review of 145 peer-reviewed journal articles related to PFO that is intended to encourage reflection on PFO detection methods and on the possible association between PFO and stroke. There is a heightened debate on whether aviators, astronauts, and scuba divers should go through screening for PFO. Because it is a source of an important controversy, we prefer to present the findings in the format of a neutral bibliographic review independent of our own opinions. Each cited peer-reviewed article includes a short summary in which we attempt to present potential parallels with the pathophysiology of decompression bubbles. Two types of articles are summarized, as follows. First, we report the original clinical and physiological findings which focus on PFO. The consistent reporting sequence begins by describing the method of detection of PFO and goal of the study, followed by bulleted results, and finally the discussion and conclusion. Second, we summarize from review papers the issues related only to PFO. At the end of each section, an abstract with concluding remarks based on the cited articles provides guidelines.

NASA Discipline Environmental Health↗

Compaction agent clarification of microbial lysates

Recombinant proteins are often purified from microbial lysates containing high concentrations of nucleic acids. Pre-purification steps such as nuclease addition or precipitation with polyethyleneimine or ammonium sulfate are normally required to reduce viscosity and to eliminate competing polyanions before anion exchange chromatography. We report that small polycationic compaction agents such as spermine selectively precipitate nucleic acids during or after Escherichia coli lysis, allowing DNA and RNA to be pelleted with the insoluble cell debris. Analysis by spectrophotometry and protein assay confirmed a significant reduction in the concentration of nucleic acids present, with preservation of protein. Lysate viscosity is greatly reduced, facilitating subsequent processing. We have used 5mM spermine to remove nucleic acids from E. coli lysate in the purification of a hexahistidine-tagged HIV reverse transcriptase.

NASA Discipline Environmental Health↗