Search NASA⌕ Search

NASA NTRS · 20040141490

Why do pitched horizontal lines have such a small effect on visually perceived eye level?

Abstract

In two experiments, visually perceived eye level (VPEL) was measured while subjects viewed two-dimensional displays that were either upright or pitched 20 degrees top-toward or 20 degrees top-away from them. In Experiment 1, it was demonstrated that binocular exposure to a pair of pitched vertical lines or to a pitched random dot pattern caused a substantial upward VPEL shift for the top-toward pitched array and a similarly large downward shift for the top-away array. On the other hand, the same pitches of a pair of horizontal lines (viewed binocularly or monocularly) produced much smaller VPEL shifts. Because the perceived pitch of the pitched horizontal line display was nearly the same as the perceived pitch of the pitched vertical line and dot array, the relatively small influence of pitched horizontal lines on VPEL cannot be attributed simply to an underestimation of their pitch. In Experiment 2, the effects of pitched vertical lines, dots, and horizontal lines on VPEL were again measured, together with their effects on resting gaze direction (in the vertical dimension). As in Experiment 1, vertical lines and dots caused much larger VPEL shifts than did horizontal lines. The effects of the displays on resting gaze direction were highly similar to their effects on VPEL. These results are consistent with the hypothesis that VPEL shifts caused by pitched visual arrays are due to the direct influence of these arrays on the oculomotor system and are not mediated by perceived pitch.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Post, R. B., Welch, R. B., Clark, V. D.. 2000-05-01. Why do pitched horizontal lines have such a small effect on visually perceived eye level?. https://ntrs.nasa.gov/citations/20040141490

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

A multiparameter wearable physiologic monitoring system for space and terrestrial applications

A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

NASA Center ARC↗

Methods for the culture of C. elegans and S. cerevisiae in microgravity

To support the study of the effects of microgravity on biological systems, our group is developing and testing methods that allow the cultivation of C. elegans and S. cerevisiae in microgravity. Our aim is to develop the experimental means by which investigators may conduct peer reviewed biological experiments with C. elegans or S. cerevisiae in microgravity. Our protocols are aimed at enabling investigators to grow these organisms for extended periods during which samples may be sub-cultured, collected, preserved, frozen, and/or returned to earth for analysis. Data presented include characterization of the growth phenotype of these organisms in liquid medium in OptiCells(TM) (Biocrystal, LTD).

NASA Center ARC↗

The relationship between perceived length and egocentric location in Muller-Lyer figures with one versus two chevrons

We examined the apparent dissociation of perceived length and perceived position with respect to the Muller-Lyer (M-L) illusion. With the traditional (two-chevron) figure, participants made accurate open-loop pointing responses at the endpoints of the shaft, despite the presence of a strong length illusion. This apparently non-Euclidean outcome replicated that of Mack, Heuer, Villardi, and Chambers (1985) and Gillam and Chambers (1985) and contradicts any theory of the M-L illusion in which mislocalization of shaft endpoints plays a role. However, when one of the chevrons was removed, a constant pointing error occurred in the predicted direction, as well as a strong length illusion. Thus, with one-chevron stimuli, perceived length and location were no longer completely dissociated. We speculated that the presence of two opposing chevrons suppresses the mislocalizing effects of a single chevron, especially for figures with relatively short shafts.

NASA Center ARC↗