NASA NTRS ยท 20050201784
Floating Potential Probe Deployed on the International Space Station
Abstract
In the spring and summer of 2000, at the request of the International Space Station (ISS) Program Office, a Plasma Contactor Unit Tiger Team was set up to investigate the threat of the ISS arcing in the event of a plasma contactor outage. Modeling and ground tests done under that effort showed that it is possible for the external structure of the ISS to become electrically charged to as much as -160 V under some conditions. Much of this work was done in anticipation of the deployment of the first large ISS solar array in November 2000. It was recognized that, with this deployment, the power system would be energized to its full voltage and that the predicted charging would pose an immediate threat to crewmembers involved in extravehicular activities (EVA's), as well as long-term damage to the station structure, were the ISS plasma contactors to be turned off or stop functioning. The Floating Potential Probe was conceived, designed, built, and deployed in record time by a crack team of scientists and engineers led by the NASA Glenn Research Center in response to ISS concerns about crew safety.
Keep this discovery
Explore connections, maps & timelines
Ferguson, Dale C.. 2001-03-01. Floating Potential Probe Deployed on the International Space Station. https://ntrs.nasa.gov/citations/20050201784
Cite the original work for its findings. Save a collection to share your selection of sources.