Search NASASearch

NASA NTRS · 20050203969

Unitized Regenerative Fuel Cell System Model Development

Abstract

A Unitized Regenerative Fuel Cell (URFC) Energy Storage System is being developed at the NASA Glenn Research Center. This URFC system is unique in that it uses the surface area of the hydrogen and oxygen storage tanks as radiating heat surfaces for overall thermal control of the system. The tank surfaces also play an important role in the temperature control of regenerative gas dryers/humidifiers used to dry the hydrogen and oxygen gases produced by electrolysis during the charging and also used to humidify the hydrogen and oxygen gases used by fuel cell during the discharging of the URFCS. A bi- directional pressure controller is used to control the pressure of the oxygen and hydrogen gas inside the URFC stack during both charging and discharging of the URFC system. A water storage accumulator is used to store water reactant and control water pressure inside the URFC stack.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Burke, Kenneth A., Jakupca, Ian. 2003-12-12. Unitized Regenerative Fuel Cell System Model Development. https://ntrs.nasa.gov/citations/20050203969