Search NASA⌕ Search

NASA NTRS · 20050215463

Modeling contamination migration on the Chandra X-Ray Observatory

Abstract

During its first 5 years of operation, the cold (-60 C) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), on board the Chandra X-ray Observatory, has accumulated a contaminating layer that attenuates the low-energy x rays. To assist in assessing the likelihood of successfully baking off the contaminant, members of the Chandra Team developed contamination-migration simulation software. The simulation follows deposition onto and (temperature-dependent) vaporization from surfaces comprising a geometrical model of the Observatory. A separate thermal analysis, augmented by on-board temperature monitoring, provides temperatures for each surface of the same geometrical model. This paper describes the physical basis for the simulations, the methodologies, and the predicted migration of the contaminant for various bake-out scenarios and assumptions.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O'Dell, Stephen L., Swartz, Douglas A., Anderson, Scot K., Chen, Kenny C., Giordano, Rino J., Knollenberg, Perry J., Morris, Peter A., Plucinsky, Paul P., Tice, Neil W., Tran, Hien. 2005-01-01. Modeling contamination migration on the Chandra X-Ray Observatory. https://ntrs.nasa.gov/citations/20050215463

Cite the original work for its findings. Save a collection to share your selection of sources.