Search NASA⌕ Search

NASA NTRS · 20050239576

Effect of Operating Frequency and Fill Time on PDE-Ejector Thrust Performance

Abstract

Thrust measurements for a pulse detonation engine (PDE)-ejector system were determined for a range of operating frequencies. Various length tubular ejectors were utilized. The results were compared to the measurements of the thrust output of the PDE alone to determine the enhancement provided by each ejector configuration at the specified frequencies. Ethylene was chosen as the fuel, with an equi-molar mixture of nitrogen and oxygen acting as the oxidizer. The propellant was kept at an equivalence ratio of one during all the experiments. The system was operated for frequencies between 20 and 50 Hz. The parameter space of the study included PDE operation frequency, ejector length, overlap percentage, the radius of curvature for the ejector inlets, and duration of the time allowed between cycles. The results of the experiments showed a maximum thrust augmentation of 120% for a PDE-ejector configuration at a frequency of 40Hz with a fill time of 10 ms.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Landry, K., Santoro, Robert J., Pal, Sibtosh, Shehadeh, R., Bouvet, N., Lee, S.-Y.. 2005-11-01. Effect of Operating Frequency and Fill Time on PDE-Ejector Thrust Performance. https://ntrs.nasa.gov/citations/20050239576

Cite the original work for its findings. Save a collection to share your selection of sources.