NASA NTRS ยท 20060043990
Improved target handoff for single cycle instrument placement
Abstract
Single Cycle Instrument Placement(SCIP)could dramatically increase the speed of various planetary rover operations. JPL is validating SCIP for use on its upcoming Mars Science Laboratory mission. Two major sources of error in the implementation submitted for validation were imprecision in selecting a distant target and error introduced while handing the target off to the rover's hazard cameras (hazcams). We have added the capability to designate a target using high resolution cameras (pancams) and then hand off to medium resolution cameras (navcams) with little error later in the traverse. We implemented several options for handoff from navcams to hazcams. We evaluated their performance on several test cases. Two methods produced average handoff error of 1 pixel when successful, but these only worked in half of the tests. Two other methods reliably produced about 10 pixels of error. None reliably reach the goal of 1 pixel handoff accuracy.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Madison, Richard. 2006-03-04. Improved target handoff for single cycle instrument placement. https://ntrs.nasa.gov/citations/20060043990
Cite the original work for its findings. Save a collection to share your selection of sources.