High Temperature Evaluation of an Active Clearance Control System Concept
Abstract
A mechanically actuated blade tip clearance control concept was evaluated in a nonrotating test rig to quantify secondary seal leakage at elevated temperatures. These tests were conducted to further investigate the feasibility of actively controlling the clearance between the rotor blade tips and the surrounding shroud seal in the high pressure turbine (HPT) section of a turbine engine. The test environment simulates the state of the back side of the HPT shroud seal with pressure differentials as high as 120 psig and temperatures up to 1000 F. As expected, static secondary seal leakage decreased with increasing temperature. At 1000 F, the test rig's calculated effective clearance (at 120 psig test pressure) was 0.0003 in., well within the industry specified effective clearance goal.
Keep this discovery
Explore connections, maps & timelines
Taylor, Shawn C., Steinetz, Bruce M., Oswald, Jay J.. 2006-11-01. High Temperature Evaluation of an Active Clearance Control System Concept. https://ntrs.nasa.gov/citations/20060056456