The STS-121/ULF1.1 mission was the maiden flight of the Programmable Thermostat Module (PTM) system used to control the 28 V shell heaters on the Multi-Purpose Logistics Module (MPLM). These PTMs, in conjunction with a Data Recorder Module (DRM), provide continuous closed loop temperature control and data recording of MPLM on-orbit heater operations. This paper will discuss the hardware design, development, test and verification (DDT&V) activities performed at the Marshall Space Flight Center (MSFC) as well as the operational implementation and mission performance.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Clark, Dallas, Glasgow, Shaun, Reagan, Shawn, Presson, Keith, Howard, David, Smith, Dennis. 2007-01-01. Programmable Thermostat Module Upgrade for the Multi-Purpose Logistics Module. https://searchnasa.com/record/nasa%3A20070018807/programmable-thermostat-module-upgrade-for-the-multi-purpose-logistics-module