Abstract

This paper describes an experimental study to investigate the effectiveness of using thermoelectric converters (TECs) to control the loop heat pipe (LHP) operating temperature. Tests were conducted on an LHP having two evaporators and two condensers. Each evaporator has its own integral compensation chamber (CC). One side of the TEC is attached to the CC, and the other side is connected to the evaporator through a copper thermal strap. A bi-polar power supply is used to provide the power for the operation of each TEC. The bipolar supply will automatic change the direction of the current to the TEC depending on whether the CC requires heating or cooling in order to maintain its temperature at the desired set point. When cooling the CC, the heat pumped by the TEC plus the power needed to operate the TEC is dissipated to the evaporator, and is ultimately transmitted to the condenser. When heating the CC, the TEC can draw heat from the evaporator to supplement the required control heater power. Test results showed that the TEC could control the LHP operating temperature within h1K of the set point temperature. The control heater power required for TEC operation was also much less than that of using electrical heaters.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ku, Jentung, Nagano, Hosei. 2006-06-26. Using Thermoelectric Converters for Loop Heat Pipe Operating Temperature Control. https://ntrs.nasa.gov/citations/20080039174