Search NASA⌕ Search

NASA NTRS · 20100032407

Miniature MMIC Low Mass/Power Radiometer Modules for the 180 GHz GeoSTAR Array

Abstract

We have developed and demonstrated miniature 180 GHz Monolithic Microwave Integrated Circuit (MMIC) radiometer modules that have low noise temperature, low mass and low power consumption. These modules will enable the Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR) of the Precipitation and All-weather Temperature and Humidity (PATH) Mission for atmospheric temperature and humidity profiling. The GeoSTAR instrument has an array of hundreds of receivers. Technology that was developed included Indium Phosphide (InP) MMIC Low Noise Amplifiers (LNAs) and second harmonic MMIC mixers and I-Q mixers, surface mount Multi-Chip Module (MCM) packages at 180 GHz, and interferometric array at 180 GHz. A complete MMIC chip set for the 180 GHz receiver modules (LNAs and I-Q Second harmonic mixer) was developed. The MMIC LNAs had more than 50% lower noise temperature (NT=300K) than previous state-of-art and MMIC I-Q mixers demonstrated low LO power (3 dBm). Two lots of MMIC wafers were processed with very high DC transconductance of up to 2800 mS/mm for the 35 nm gate length devices. Based on these MMICs a 180 GHz Multichip Module was developed that had a factor of 100 lower mass/volume (16x18x4.5 mm3, 3g) than previous generation 180 GHz receivers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kangaslahti, Pekka, Tanner, Alan, Pukala, David, Lambrigtsen, Bjorn, Lim, Boon, Mei, Xiaobing, Lai, Richard. 2010-06-22. Miniature MMIC Low Mass/Power Radiometer Modules for the 180 GHz GeoSTAR Array. https://ntrs.nasa.gov/citations/20100032407

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The Correlation Radiometer - A New Application in MM-Wave Total Power Radiometry

We describe the design and performance of a 180 GHz correlation radiometer suitable for remote sensing. The radiometer provides continuous comparisons between a the observed signal and a reference load to provide stable radiometric baselines. The radiometer was assembled and tested using parts from the GeoSTAR-II instrument and is fully compatible with operation in a synthetic aperture radiometer or as a standalone technology for use in microwave sounding and imaging. This new radiometer was tested over several days easily demonstrating the required 6 hour stability requirement for observations of mean brightness temperature for a geostationary instrument.

Monolithic Microwave Integrated Circuit (MMIC)↗

GEOSTAR-II: A Prototype Water Vapor Imager/Sounder for the Path Mission

We describe the development and progress of the GeoSTAR-II risk reduction activity for the NASA Earth Science Decadal Survey PATH Mission. The activity directly addresses areas of technical risk including the system design, low noise receiver production, sub-array development, signal distribution and digital signal processing.

Monolithic Microwave Integrated Circuit (MMIC)↗