NASA NTRS · 20100033115
Spatially-Resolved Beam Current and Charge-State Distributions for the NEXT Ion Engine
Abstract
Plume characterization tests with the 36-cm NEXT ion engine are being performed at The Aerospace Corporation using engineering-model and prototype-model thrusters. We have examined the beam current density and xenon charge-state distribution as functions of position on the accel grid. To measure the current density ratio j++/j+, a collimated Eprobe was rotated through the plume with the probe oriented normal to the accel electrode surface at a distance of 82 cm. The beam current density jb versus radial position was measured with a miniature planar probe at 3 cm from the accel. Combining the j++/j+ and jb data yielded the ratio of total Xe+2 current to total Xe+1 current (J++/J+) at forty operating points in the standard throttle table. The production of Xe+2 and Xe+3 was measured as a function of propellant utilization to support performance and lifetime predictions for an extended throttle table. The angular dependence of jb was measured at intermediate and far-field distances to assist with plume modeling and to evaluate the thrust loss due to beam divergence. Thrust correction factors were derived from the total doubles-to-singles current ratio and from the far-field divergence data
Keep this discovery
Explore connections, maps & timelines
Pollard, James E., Diamant, Kevin D., Crofton, Mark W., Patterson, Michael J., Soulas, George C.. 2010-09-01. Spatially-Resolved Beam Current and Charge-State Distributions for the NEXT Ion Engine. https://ntrs.nasa.gov/citations/20100033115
Cite the original work for its findings. Save a collection to share your selection of sources.