NASA NTRS · 20110011710
Columbus Payloads Flow Rate Anomalies
Abstract
The Columbus Active Thermal Control System (ATCS) is the main thermal bus for the pressurized racks working inside the European laboratory. One of the ATCS goals is to provide proper water flow rate to each payload (P/L) by controlling actively the pressure drop across the common plenum distribution piping. Overall flow measurement performed by the Water Pump Assembly (WPA) is the only flow rate monitor available at system level and is not part of the feedback control system. At rack activation the flow rate provided by the system is derived on ground by computing the WPA flow increase. With this approach, several anomalies were raised during these 3 years on-orbit, with the indication of low flow rate conditions on the European racks FSL, BioLab, EDR and EPM. This paper reviews the system and P/Ls calibration approach, the anomalies occurred, the engineering evaluation on the measurement approach and the accuracy improvements proposed, the on-orbit test under evaluation with NASA and finally discusses possible short and long term solutions in case of anomaly confirmation.
Keep this discovery
Explore connections, maps & timelines
Quaranta, Albino, Bufano, Gaetana, DePalo, Savino, Holt, James M., Szigetvari, Zoltan, Palumberi, Sergio, Hinderer, S.. 2011-01-01. Columbus Payloads Flow Rate Anomalies. https://ntrs.nasa.gov/citations/20110011710
Cite the original work for its findings. Save a collection to share your selection of sources.