Abstract
A new probabilistic facility-centric approach to lightning strike location has been developed. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision~ith spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.
Keep this discovery
Explore connections, maps & timelines
Huddleston, Lisa L., Roeder, William p., Merceret, Francis J.. 2012-01-01. A Probabilistic, Facility-Centric Approach to Lightning Strike Location. https://ntrs.nasa.gov/citations/20120003035