NASA NTRS ยท 20120013683
Frost Growth and Densification on a Flat Surface in Laminar Flow with Variable Humidity
Abstract
Experiments are performed concerning frost growth and densification in laminar flow over a flat surface under conditions of constant and variable humidity. The flat plate test specimen is made of aluminum-6031, and has dimensions of 0.3 mx0.3 mx6.35 mm. Results for the first variable humidity case are obtained for a plate temperature of 255.4 K, air velocity of 1.77 m/s, air temperature of 295.1 K, and a relative humidity continuously ranging from 81 to 54%. The second variable humidity test case corresponds to plate temperature of 255.4 K, air velocity of 2.44 m/s, air temperature of 291.8 K, and a relative humidity ranging from 66 to 59%. Results for the constant humidity case are obtained for a plate temperature of 263.7 K, air velocity of 1.7 m/s, air temperature of 295 K, and a relative humidity of 71.6 %. Comparisons of the data with the author's frost model extended to accommodate variable humidity suggest satisfactory agreement between the theory and the data for both constant and variable humidity.
Keep this discovery
Explore connections, maps & timelines
Kandula, M.. 2012-01-01. Frost Growth and Densification on a Flat Surface in Laminar Flow with Variable Humidity. https://ntrs.nasa.gov/citations/20120013683
Cite the original work for its findings. Save a collection to share your selection of sources.