Search NASA⌕ Search

NASA NTRS · 20140011312

Wind Turbine Contingency Control Through Generator De-Rating

Abstract

Maximizing turbine up-time and reducing maintenance costs are key technology drivers for wind turbine operators. Components within wind turbines are subject to considerable stresses due to unpredictable environmental conditions resulting from rapidly changing local dynamics. In that context, systems health management has the aim to assess the state-of-health of components within a wind turbine, to estimate remaining life, and to aid in autonomous decision-making to minimize damage to the turbine. Advanced contingency control is one way to enable autonomous decision-making by providing the mechanism to enable safe and efficient turbine operation. The work reported herein explores the integration of condition monitoring of wind turbines with contingency control to balance the trade-offs between maintaining system health and energy capture. The contingency control involves de-rating the generator operating point to achieve reduced loads on the wind turbine. Results are demonstrated using a high fidelity simulator of a utility-scale wind turbine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Frost, Susan, Goebel, Kai, Balas, Mark. 2013-10-07. Wind Turbine Contingency Control Through Generator De-Rating. https://ntrs.nasa.gov/citations/20140011312

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging - Power Die, Power Module, and Converter Level - Part 1

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. To increase power density, performance, efficiency, and reliability and reduce cost, innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental research and development related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics; packaging materials; thermal materials and interfaces; fluid-based thermal management technologies; reliability; condition monitoring; and prognostics. To address these important aspects, this Special Section on Multiphysics Aspects of Power Electronics Packaging includes several articles to be published in two parts. More details are given below on the articles included in the first part.

condition monitoring↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. A recently proposed method to capture the rolling element bearing degradation provides the groundwork for new indicator families utilizing the generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the National Renewable Energy Laboratory Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox; hence the complexity of the vibration signals is similar to a real case. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗