Search NASA⌕ Search

NASA NTRS · 20150017757

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

Abstract

International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kim, Jong S., Teti, Nicholas M.. 2015-07-12. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories. https://ntrs.nasa.gov/citations/20150017757

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal↗

Simulating the Lunar Thermal Environment for the Surface-Deployed LEMS Artemis III TVAC Test

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. Presented is the system thermal vacuum test plan and configuration to validate the thermal control system performance in a flight-like environment. The test will measure the nighttime heat leaks for the bus and 18 seismometers to ensure lunar night survival and operability.

Thermal↗

Alternate Approach to Multi Layer Insulation Modeling to Reduce Node Count

For models with a limitation on the overall node count, the typical approach to Multi-Layer Insulation (MLI) modeling may generate nodes that are necessary for the analysis, but do not represent components of particular interest. This leaves fewer nodes that can be utilized to model components of greater importance than the MLI. A common approach to modeling MLI is to include a separate MLI node representing the outer layer of the insulation and a radiative coupling based on the area multiplied by an effective emissivity. Therefore, wherever insulation is included, one node is needed for the underlying surface and another node for the insulation. Since many spacecraft and instruments include MLI covering a sizable portion of their designs, this may result in a considerable number of nodes being used for MLI. An alternate method to MLI modeling was developed that eliminates the MLI node, while still preserving the effect of the insulation for the underlying surface, thereby increasing the available nodes that could be used elsewhere in the model. This approach relies on preserving the baseline reflectivity, while reducing the absorptivity (based on the blanket effective emittance) and including a transparency. An inactive second surface is placed just behind the base surface that fully absorbs any energy that is transmitted without including its effect in the model. In essence, this approach applies only the energy that makes it through the blanket to the underlying surface. This method was tested out on the Roman Space Telescope model in local areas in preparation for its use in the generation of a launch model, which is constrained in the allowable node count. This paper documents the performance of the method and presents a comparison between the One-Node MLI method and the traditional two node MLI approach.

Thermal↗