Search NASASearch

NASA NTRS · 20160008695

Multimode Bolometer Development for the PIXIE Instrument

Abstract

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With approximately 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nagler, Peter C., Crowley, Kevin T., Denis, Kevin L., Devasia, Archana M., Fixsen, Dale J., Kogut, Alan J., Manos, George, Porter, Scott, Stevenson, Thomas R.. 2016-06-26. Multimode Bolometer Development for the PIXIE Instrument. https://ntrs.nasa.gov/citations/20160008695

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Multimode Bolometer Development for the Primordial Inflation Explorer (PIXIE) Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background [1]. In this work, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a tensioning scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE