Search NASA⌕ Search

NASA NTRS · 20160010082

Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

Abstract

In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schwarz, Mark A., Kent, Craig J., Bousquet, Robert, Brown, Steven W.. 2016-08-30. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors. https://ntrs.nasa.gov/citations/20160010082

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Spurious Signal in SMAP Fourth Stokes Parameter

The radiometer on the NASA Soil Moisture Active/Passive (SMAP) mission is a fully polarimetric instrument that operates at L-band in the spectrum window at 1400-1427 MHz protected for passive use only. A unique feature of the radiometer is the fully digital back-end which permits direct computation of the third and fourth Stokes parameters: the real and imaginary part of the correlation of signal at horizontal and vertical polarizations, respectively. In particular, the SMAP conical scanning geometry provides the opportunity to look at the global distribution of the fourth Stokes parameter, TA4, at constant incidence angle (40°). A striking feature of TA4 is the existence of a strong (±10 K) spurious signal at coastlines. This article provides examples of the spikes and an explanation of the cause. Simulations have shown that the spurious signal is associated with antenna imperfections, such as cross polarization coupling and phase mismatch between polarizations.

radiometry↗