Search NASA⌕ Search

NASA NTRS · 20160010297

Sensitivity Analysis of the Integrated Medical Model for ISS Programs

Abstract

Sensitivity analysis estimates the relative contribution of the uncertainty in input values to the uncertainty of model outputs. Partial Rank Correlation Coefficient (PRCC) and Standardized Rank Regression Coefficient (SRRC) are methods of conducting sensitivity analysis on nonlinear simulation models like the Integrated Medical Model (IMM). The PRCC method estimates the sensitivity using partial correlation of the ranks of the generated input values to each generated output value. The partial part is so named because adjustments are made for the linear effects of all the other input values in the calculation of correlation between a particular input and each output. In SRRC, standardized regression-based coefficients measure the sensitivity of each input, adjusted for all the other inputs, on each output. Because the relative ranking of each of the inputs and outputs is used, as opposed to the values themselves, both methods accommodate the nonlinear relationship of the underlying model. As part of the IMM v4.0 validation study, simulations are available that predict 33 person-missions on ISS and 111 person-missions on STS. These simulated data predictions feed the sensitivity analysis procedures. The inputs to the sensitivity procedures include the number occurrences of each of the one hundred IMM medical conditions generated over the simulations and the associated IMM outputs: total quality time lost (QTL), number of evacuations (EVAC), and number of loss of crew lives (LOCL). The IMM team will report the results of using PRCC and SRRC on IMM v4.0 predictions of the ISS and STS missions created as part of the external validation study. Tornado plots will assist in the visualization of the condition-related input sensitivities to each of the main outcomes. The outcomes of this sensitivity analysis will drive review focus by identifying conditions where changes in uncertainty could drive changes in overall model output uncertainty. These efforts are an integral part of the overall verification, validation, and credibility review of IMM v4.0.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Goodenow, D. A., Myers, J. G., Arellano, J., Boley, L., Garcia, Y., Saile, L., Walton, M., Kerstman, E., Reyes, D., Young, M.. 2016-02-08. Sensitivity Analysis of the Integrated Medical Model for ISS Programs. https://ntrs.nasa.gov/citations/20160010297

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation of the Nasa Integrated Medical Model: a Space Flight Medical Risk Prediction Tool

The Human Research Program funded the development of the Integrated Medical Model (IMM) to quantify the medical component of overall mission risk. The IMM uses Monte Carlo simulation methodology, incorporating space flight and ground medical data, to estimate the probability of mission medical outcomes and resource utilization. To determine the credibility of IMM output, the IMM project team completed two validation studies that compared IMM predicted output to observed medical events from a selection of Shuttle Transportation System (STS) and International Space Station (ISS) missions. The validation study results showed that the IMM underpredicted the occurrence of ~10% of the modeled medical conditions for the STS missions and overpredicted ~20% of the modeled medical conditions for the ISS missions. These findings imply that the strength of IMM predictions to inform decisions depends on simulated mission specifications including length. This discrepancy could result from medical recording differences between ISS and STS that possibly influence observed incidence rates, IMM combining all "mission type" data as constant occurrence rate or fixed proportion across both mission types, misspecification of symptoms to conditions, and gaps in the literature informing the model. Some of these issues will be alleviated by updating the IMM source data through incorporation of the observed validation data.

medical equipment↗

The Integrated Medical Model: Outcomes from Independent Review

In 2016, the Integrated Medical Model (IMM) v4.0 underwent an extensive external review in preparation for transition to an operational status. In order to insure impartiality of the review process, the Exploration Medical Capabilities Element of NASA's Human Research Program convened the review through the Systems Review Office at NASA Goddard Space Flight Center (GSFC). The review board convened by GSFC consisted of persons from both NASA and academia with expertise in the fields of statistics, epidemiology, modeling, software development, aerospace medicine, and project management (see Figure 1). The board reviewed software and code standards, as well as evidence pedigree associated with both the input and outcomes information. The board also assesses the models verification, validation, sensitivity to parameters and ability to answer operational questions. This talk will discuss the processes for designing the review, how the review progressed and the findings from the board, as well as summarize the IMM project responses to those findings. Overall, the board found that the IMM is scientifically sound, represents a necessary, comprehensive approach to identifying medical and environmental risks facing astronauts in long duration missions and is an excellent tool for communication between engineers and physicians. The board also found IMM and its customer(s) should convene an additional review of the IMM data sources and to develop a sustainable approach to augment, peer review, and maintain the information utilized in the IMM. The board found this is critically important because medical knowledge continues to evolve. Delivery of IMM v4.0 to the Crew Health and Safety (CHS) Program will occur in the 2017. Once delivered for operational decision support, IMM v4.0 will provide CHS with additional quantitative capability in to assess astronaut medical risks and required medical capabilities to help drive down overall mission risks.

medical equipment↗