Search NASASearch

NASA NTRS · 20160012341

Microgravity-Driven Optic Nerve/Sheath Biomechanics Simulations

Abstract

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Current thinking suggests that the ocular changes observed in VIIP syndrome are related to cephalad fluid shifts resulting in altered fluid pressures [1]. In particular, we hypothesize that increased intracranial pressure (ICP) drives connective tissue remodeling of the posterior eye and optic nerve sheath (ONS). We describe here finite element (FE) modeling designed to understand how altered pressures, particularly altered ICP, affect the tissues of the posterior eye and optic nerve sheath (ONS) in VIIP. METHODS: Additional description of the modeling methodology is provided in the companion IWS abstract by Feola et al. In brief, a geometric model of the posterior eye and optic nerve, including the ONS, was created and the effects of fluid pressures on tissue deformations were simulated. We considered three ICP scenarios: an elevated ICP assumed to occur in chronic microgravity, and ICP in the upright and supine positions on earth. Within each scenario we used Latin hypercube sampling (LHS) to consider a range of ICPs, ONH tissue mechanical properties, intraocular pressures (IOPs) and mean arterial pressures (MAPs). The outcome measures were biomechanical strains in the lamina cribrosa, optic nerve and retina; here we focus on peak values of these strains, since elevated strain alters cell phenotype and induce tissue remodeling. In 3D, the strain field can be decomposed into three orthogonal components, denoted as first, second and third principal strains. RESULTS AND CONCLUSIONS: For baseline material properties, increasing ICP from 0 to 20 mmHg significantly changed strains within the posterior eye and ONS (Fig. 1), indicating that elevated ICP affects ocular tissue biomechanics. Notably, strains in the lamina cribrosa and retina became less extreme as ICP increased; however, within the optic nerve, the occurrence of such extreme strains greatly increased as ICP was elevated (Fig. 2). In particular, c. 48 of simulations in the elevated ICP condition showed peak strains in the optic nerve that exceeded the strains expected on earth. Such extreme strains are likely important, since they represent a larger signal for mechano-responsive resident cells [2]. The models predicted little to no anterior motion of the prelaminar neural tissue (optic nerve swelling, or papilledema, secondary to axoplasmic stasis), typically seen with elevated ICP. Specialized FE models to capture axoplasmic stasis would be required to study papilledema. These results suggest that the most notable effect of elevated ICP may occur via direct optic nerve loading, rather than through connective tissue deformation. These FE models can inform the design of future studies designed to bridge the gap between biomechanics and pathophysiological function in VIIP.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ethier, C. R., Feola, A., Myers, J. G., Nelson, E., Raykin, J., Samuels, B.. 2016-02-08. Microgravity-Driven Optic Nerve/Sheath Biomechanics Simulations. https://ntrs.nasa.gov/citations/20160012341

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Cross-Cutting Computational Modeling Project: Integrative Modeling Approach

A wide range of computational models and analyses have been applied to spaceflight risk assessment and countermeasure development. The benefits of using computational modeling to enhance Human Research Program (HRP) goals include the ability to mathematically represent physiological systems, integrate multiple, discrete experimental measures, span multiple temporal and spatial scales, determine important factors within the system and provide estimates of unmeasurable quantities. In the area of application, computational models provide a means of developing simulations to test hypotheses, determining key factors of the system to aid experimental design and bridging gaps in sparse data by mathematically simulating large populations. Specifically, computational models and their supporting analysis tools have the proven potential to integrate analyses of risk factors to enhance mission planning and preparation capabilities and to inform spacecraft design and countermeasure development. Appropriately applied, computational models may allow intelligent, unbiased physiological parameter assessment to enable hypothesis testing and model based design of experiments. HRP recently formed the Computational Modeling Project (CMP), managed out of Glenn Research Center, as a cross-cutting activity aimed at leveraging the growing power and acceptance of computational modeling in informing clinical, physiological, and biological studies. This presentation will provide an overview of the challenges and opportunities in implementing various forms of computational models in support of the HRPs path to risk reduction.

biomechanics

Modeling Microgravity Induced Fluid Redistribution Autoregulatory and Hydrostatic Enhancements

Space flight induces a marked cephalad (headward) redistribution of blood and interstitial fluid potentially resulting in a loss of venous tone and reduction in heart muscle efficiency upon introduction into the microgravity environment. Using various types of computational models, we are investigating how this fluid redistribution may induce intracranial pressure changes, relevant to reported reductions in astronaut visual acuity, part of the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Methods: We utilize a lumped parameter cardiovascular system (CVS) model, augmented by compartments comprising the cerebral spinal fluid (CSF) space, as the primary tool to describe how microgravity, and the associated lack of hydrostatic gradient, impacts fluid redistribution. Models of ocular fluid pressures and biomechanics then accept the output of the above model as boundary condition input to allow more detailed, local analysis (see IWS Abstract by Ethier et al.). Recently, we enhanced the capabilities our previously reported CVS model through the implementation of robust autoregulatory mechanisms and a more fundamental approach to the implementation of hydrostatic mechanisms. Modifying the approach of Blanco et al., we implemented auto-regulation in a quasi-static manner, as an averaged effect across the span of one heartbeat. This approach reduced the higher frequency perturbations from the regulatory mechanism and was intended to allow longer simulation times (days) than models that implement within-beat regulatory mechanisms (minutes). A more fundamental approach to hydrostatics was implemented by a quasi-1D approach, in which compartment descriptions include compartment length, orientation and relative position, allowed for modeling of body orientation, relative body positioning and, in the future, alternative gravity environments. At this time the inclusion of hydrostatic mechanisms supplies additional capabilities to train and validate the CVS model with terrestrial data. Results and Conclusions: With the implementation of auto-regulation and hydrostatic modeling capabilities, the model performs as expected in the maintaining the CA (Central Artery) compartment pressure when simulating orientations ranging from supine to standing. The model appears to generally overpredict heart rate and thus cardiac output, possibly indicating sensitivity to the nominal heart rate, which is used as an initial set point of the regulation mechanisms. Despite this sensitivity, the model performs consistently for many hours of simulation time, indicating the success of our quasi-static implementation approach.

biomechanics