Search NASA⌕ Search

NASA NTRS · 20160014660

Analysis of CrIS ATMS and AIRS AMSU Data Using Scientifically Equivalent Retrieval Algorithms

Abstract

Monthly mean August 2014 Version-6.28 AIRS and CrIS products agree well with OMPS and CERES, and reasonably well with each other. Version-6.28 CrIS total precipitable water is biased dry compared to AIRS. AIRS and CrIS Version-6.36 water vapor products are both improved compared to Version-6.28. Version-6.36 AIRS and CrIS total precipitable water also shows improved agreement with each other. AIRS Version-6.36 total ozone agrees even better with OMPS than does AIRS Version-6.28, and gives reasonable results during polar winter where OMPS does not generate products. CrIS and ATMS are high spectral resolution IR and Microwave atmospheric sounders currently flying on the SNPP satellite, and are also scheduled for flight on future NPOESS satellites. CrIS/ATMS have similar sounding capabilities to those of the AIRS/AMSU sounder suite flying on EOS Aqua. The objective of this research is to develop and implement scientifically equivalent AIRS/AMSU and CrIS/ATMS retrieval algorithms with the goal of generating a continuous data record of AIRS/AMSU and CrIS/ATMS level-3 data products with a seamless transition between them in time. To achieve this, monthly mean AIRS/AMSU and CrIS/ATMS retrieved products, and more importantly their interannual differences, should show excellent agreement with each other. The currently operational AIRS Science Team Version-6 retrieval algorithm has generated 14 years of level-3 data products. A scientifically improved AIRS Version-7 retrieval algorithm is expected to become operational in 2017. We see significant improvements in water vapor and ozone in Version-7 retrieval methodology compared to Version-6.We are working toward finalization and implementation of scientifically equivalent AIRS/AMSU and CrIS/ATMS Version-7 retrieval algorithms to be used for the eventual processing of all AIRS/AMSU and CrIS/ATMS data. The latest version of our retrieval algorithm is Verison-6.36, which includes almost all the improvements we want in Version-7. Version-6.28 has been used to process both AIRS and CrIS data for August 2014. This poster compares August 2014 monthly mean Version-6.28 AIRS/AMSU and CrIS/ATMS products with each other, and also with monthly mean products obtained using AIRS Version-6. AIRS and CrIS results using Version-6.36 are presented for April 15, 2016. These demonstrate further improvements since Version-6.28. The new results also show improved agreement of Version-6.36 AIRS and CrIS products with each other. Version-6.36 is not yet optimized for CrIS ozone products.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Susskind, Joel, Kouvaris, Louis, Iredell, Lena, Blaisdell, John. 2016-12-12. Analysis of CrIS ATMS and AIRS AMSU Data Using Scientifically Equivalent Retrieval Algorithms. https://ntrs.nasa.gov/citations/20160014660

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Assessing the Impacts of Two Averaging Methods on AIRS Level 3 Monthly Products and Multi-Year Monthly Means

The Atmospheric Infrared Sounder (AIRS) onboard NASA’s Aqua satellite provides more than 16 years of data. Its monthly gridded (Level 3) product has been widely used for climate research and applications. Since counts of successful soundings in a grid cell are used to derive monthly averages, this “Averaged By Observations (ABO)” approach effectively gives equal importance to all participating soundings within a month. It is conceivable, then, that days with more observations due to day-to-day orbit shift and regimes with better retrieval skills, will contribute disproportionately to the monthly average within a cell. Alternatively, the AIRS Level 3 monthly product can be produced through an "Averaged By Days (ABD)” approach, where the monthly mean in a grid cell is a simple average of the daily means. The effects of these averaging methods on the AIRS version 6 monthly product are assessed quantitatively using temperature and water vapor at surface and 500hPa. The ABO method results in a warmer (slightly colder) global mean temperature at surface (500hPa) and a drier global mean water vapor than ABD method. The AIRS multi-year monthly mean temperature and water vapor from both methods are also compared with the Modern-Era Retrospective analysis for Research and Applications – 2 (MERRA-2) product and evaluated with a simulation experiment, indicating the ABD method has less error and is more closely correlated with MERRA-2. In summary, the ABD method is recommended for future versions of the AIRS Level 3 monthly product and more data services supporting Level 3 aggregation are needed.

AIRS↗

Planetary Boundary Layer Height from AIRS and MERRA-2 Products at NASA GES DISC, and Insights from Data Intercomparison

The Atmospheric Infrared Sounder (AIRS) is the hyperspectral infrared sounder onboard NASA's Aqua satellite, launched in 2002. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), in collaboration with NASA Sounder Team at JPL, provides processing, archiving, and distribution services for NASA sounders: the Aqua AIRS mission and the subsequent Suomi-National Polar-orbiting Partnership Cross-track Infrared Sounder (CrIS) mission. The Planetary Boundary Layer (PBL) Height is a new variable added in the AIRS Version 6 support product. It is derived based on gradients of the retrieved atmospheric thermodynamic profile, and gives the pressure at the top of PBL over the ocean. The GES DISC also provides services for the second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) product generated by the Goddard Earth Observing System Model, Version 5 (GEOS-5) data assimilation system. The monthly PBL Height variable has been available in the Giovanni system, which is a Web-based application developed by the GES DISC providing a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data. In this work, we will present the monthly PBL Height data from AIRS and MERRA-2 and the services to support data intercomparison, such as access, plotting, subsetting, re-gridding, and generation of a multi-year monthly mean. We will also show intercomparison results, and evaluate whether (over the ocean) AIRS can observe PBL features similar to the reanalysis product at monthly and longer-term scales.

AIRS↗

AIRS-Only Product in Giovanni for Exploring Up-to-Date AIRS Observation and Comparing with AIRS+AMSU Product

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002 for global observations of the atmospheric state. Giovanni, a Web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important AIRS variables, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases, are available in Giovanni. AIRS is an instrument suite comprised of a hyperspectral infrared instrument (AIRS) and two multichannel microwave instruments, the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB). As HSB ceased operation in the very early stages of the AIRS mission, the AIRS project operates two parallel retrieval algorithms: one using both IR and MW measurements (AIRS+AMSU) and the other using only IR measurements (AIRS-only), which covers most of the mission duration. The AIRS+AMSU product is better quality, and the variables in Giovanni are from this product. However, generation of the AIRS+AMSU product has been suspended since the AMSU instrument anomaly occurred in late September 2016. To continue exploring up-to-date AIRS observations, the same set of variables from the AIRS-only product have been added to Giovanni by the GES DSIC. This will also support comparison of AIRS-only with AIRS+AMSU retrievals. In this presentation, we demonstrate the visualization of the AIRS-only product and plots/statistics of comparison with AIRS+AMSU product using Giovanni.

AIRS↗