Search NASA⌕ Search

NASA NTRS · 20170000303

Changes in Mouse Bone Turnover in Response to Microgravity

Abstract

Mechanical unloading during spaceflight is known to adversely affect mammalian physiology. Our previous studies using the Animal Enclosure Module on short duration Shuttle missions enabled us to identify a deficit in stem cell based-tissue regeneration as being a significant concern for long-duration spaceflight. Specifically, we found that mechanical unloading in microgravity resulted in inhibition of differentiation of mesenchymal and hematopoietic stem cells in the bone marrow compartment. Also, we observed overexpression of a cell cycle arrest molecule, CDKN1a/p21, in osteoprecursor cells on the bone surface, chondroprogenitors in the articular cartilage, and in myofibers attached to bone tissue. Specifically in bone tissue during both short (15-day) and long (30-day) microgravity experiments, we observed significant loss of bone tissue and structure in both the pelvis and the femur. After 15-days of microgravity on STS-131, pelvic ischium displayed a 6.23% decrease in bone fraction (p=0.005) and 11.91% decrease in bone thickness (p=0.002). Furthermore, during long-duration spaceflight we observed onset of an accelerated aging-like phenotype and osteoarthritic disease state indicating that stem cells within the bone tissue fail to repair and regenerate tissues in a normal manner, leading to drastic tissue alterations in response to microgravity. The Rodent Research Hardware System provides the capability to investigate these effects during long-duration experiments on the International Space Station. During the Rodent Research-1 mission 10 16-week-old female C57Bl/6J mice were exposed to 37-days of microgravity. All flight animals were euthanized and frozen on orbit for future dissection. Ground (n=10) and vivarium controls (n=10) were housed and processed to match the flight animal timeline. During this study we collected pelvis, femur, and tibia from all animal groups to test the hypothesis that stem cell-based tissue regeneration is significantly altered after 37-days of spaceflight. To do this, we will analyze differences in bone morphometric parameters using MicroCT. The pelvis, femur, and tibia are key in supporting and distributing weight under normal conditions. Therefore, we expect to see altered remodeling in flight animals in response to microgravity with respect to ground controls. In combination with histomorphometry, these results will help elucidate the complex mechanisms underlying bone tissue maintenance and stem cell regeneration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cheng-Campbell, M., Blaber, E., Almeida, E.. 2016-10-26. Changes in Mouse Bone Turnover in Response to Microgravity. https://ntrs.nasa.gov/citations/20170000303

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The CapiSorb Visible System (CVS) Demonstrations on ISS

Falling liquid film amine sorbent reactors have been successfully employed to scrub CO 2 aboard submarines for decades. However, applying such proven methods aboard orbiting and coast spacecraft is significantly challenged by the nearly weightless environment, where liquid sprays and films do not fall, and vapor bubbles and gases do not rise. The Capillary Sorbent (CapiSorb) Visible System (CVS) is a technology demonstration experiment performed aboard the ISS April 18 – 21, 2023. The system establishes stable steady thin liquid film flows in Contactor (absorber) and Degasser (desorber/stripper) replacing the passive role of gravity with the combined passive roles of surface tension, wetting, and system geometry. A TOX-0 fructose ersatz liquid sorbent is employed enabling ‘transparent’ experiments performed and filmed by the crew safely in the open cabin of the ISS. Completed objectives include demonstrations of stable passive ‘massively’ parallel planar thin film capillary flows across atmospheric pressure Contactor and sealed heated Degasser. The impacts of varying flow rate, flow direction, heat input, viscosity, positive and negative Degasser pressures, condensate collection and return, fluid distribution, interfacial stability, and others are reported. At least 49 diagnostics are recorded for digitization and subsequent thermal-fluids model validation by a single HD video downlink during the nearly 22 hours of operations. An overview of the flight hardware including description of the components, diagnostics, crew procedures, flight operations, and summary of accomplishments is reported in Ref. 1. Further details of the diagnostics, tests performed, and data reduction is reported in Ref. 2. This report collects both1,2 into a single report adding methods of data digitization, reduction, and archive along with analyses and discussions of technology impacts.

microgravity↗

The Double-Drained Drop: Symmetric Draining of Liquids from Containers with Interior Corners

An analytic solution is found for the late stage draining of a wetting capillary liquid from an interior corner. The solution exploits the symmetry of volumetric sink conditions at opposing ends of such a `double-drained' interior corner flow with applications ranging from liquid recovery in microfluidic devices on earth to liquid fuels scavenging in large fuel tanks aboard spacecraft. At long times t, the liquid depth is h~t^n, the liquid volume is V~ t^(2n), and the maximum volumetric liquid removal rate is Q~t^(2n-1), where n =-1. Representative experiments are conducted at larger length scales aboard the International Space Station and at microfluidic length scales in a terrestrial laboratory. Both sets of experiments confirm the solutions. We show that the approach offers a method to predict maximum drain rates from related geometries where a single drain location provides the required symmetry. We also show that the `fixed length' solution is one of many practical similarity solutions to the governing nonlinear evolution equation for the transient liquid profile along the interior corner. Exponential asymptotic Fourier series solutions are also found for partial corner fillling as well as draining.

microgravity↗