Abstract

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Godfrey, A., Humphreys, B., Funk, J., Perusek, G., Lewandowski, B. E.. 2017-01-23. MPCV Exercise Operational Volume Analysis. https://ntrs.nasa.gov/citations/20170005224

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The Impact of Ocular Pressures, Material Properties and Geometry on Optic Nerve Head Deformation

Alteration in intracranial pressure (ICP) has been associated with various diseases that cause visual impairment, including glaucoma, idiopathic intracranial hypertension and Visual Impairment and Intracranial Pressure (VIIP) syndrome. However, how changes in ICP lead to vision loss is unclear, although it is hypothesized to involve deformations of the tissues in the optic nerve head (ONH). Recently, understanding the effect of ICP alterations on ocular tissues has become a major concern for NASA, where 42 of astronauts that partake in long duration space missions suffer from VIIP syndrome. Astronauts with VIIP syndrome suffer from visual impairment and changes in ocular anatomy that persist after returning to earth (1). It is hypothesized that the cephalad fluid shift that occurs upon entering microgravity increases ICP, which leads to an altered biomechanical environment in the posterior globe and optic nerve sheath, and subsequently VIIP syndrome. Our goal was to develop a finite element (FE) model to simulate the acute effects of elevated ICP on the posterior eye. Here, we simulated how inter-individual differences affect the deformation of ONH tissues. Further, we examined how several different geometries influenced deformations when exposed to elevated ICP.

mathematical models

Sensitivity Analysis of the Bone Fracture Risk Model

Introduction: The probability of bone fracture during and after spaceflight is quantified to aid in mission planning, to determine required astronaut fitness standards and training requirements and to inform countermeasure research and design. Probability is quantified with a probabilistic modeling approach where distributions of model parameter values, instead of single deterministic values, capture the parameter variability within the astronaut population and fracture predictions are probability distributions with a mean value and an associated uncertainty. Because of this uncertainty, the model in its current state cannot discern an effect of countermeasures on fracture probability, for example between use and non-use of bisphosphonates or between spaceflight exercise performed with the Advanced Resistive Exercise Device (ARED) or on devices prior to installation of ARED on the International Space Station. This is thought to be due to the inability to measure key contributors to bone strength, for example, geometry and volumetric distributions of bone mass, with areal bone mineral density (BMD) measurement techniques. To further the applicability of model, we performed a parameter sensitivity study aimed at identifying those parameter uncertainties that most effect the model forecasts in order to determine what areas of the model needed enhancements for reducing uncertainty. Methods: The bone fracture risk model (BFxRM), originally published in (Nelson et al) is a probabilistic model that can assess the risk of astronaut bone fracture. This is accomplished by utilizing biomechanical models to assess the applied loads; utilizing models of spaceflight BMD loss in at-risk skeletal locations; quantifying bone strength through a relationship between areal BMD and bone failure load; and relating fracture risk index (FRI), the ratio of applied load to bone strength, to fracture probability. There are many factors associated with these calculations including environmental factors, factors associated with the fall event, mass and anthropometric values of the astronaut, BMD characteristics, characteristics of the relationship between BMD and bone strength and bone fracture characteristics. The uncertainty in these factors is captured through the use of parameter distributions and the fracture predictions are probability distributions with a mean value and an associated uncertainty. To determine parameter sensitivity, a correlation coefficient is found between the sample set of each model parameter and the calculated fracture probabilities. Each parameters contribution to the variance is found by squaring the correlation coefficients, dividing by the sum of the squared correlation coefficients, and multiplying by 100. Results: Sensitivity analyses of BFxRM simulations of preflight, 0 days post-flight and 365 days post-flight falls onto the hip revealed a subset of the twelve factors within the model which cause the most variation in the fracture predictions. These factors include the spring constant used in the hip biomechanical model, the midpoint FRI parameter within the equation used to convert FRI to fracture probability and preflight BMD values. Future work: Plans are underway to update the BFxRM by incorporating bone strength information from finite element models (FEM) into the bone strength portion of the BFxRM. Also, FEM bone strength information along with fracture outcome data will be incorporated into the FRI to fracture probability.

mathematical models

The Mathematics of Dispatchability, Revisited

Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently, it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, dispatchability has considerable theoretical as well as practical significance. One thing that hampers further work in this area is the underdeveloped theory. Moreover, the existing foundation is inadequate in certain respects. In this paper, we develop a new mathematical theory of dispatchability and its relationship to execution. We also provide several characterizations of dispatchability, including characterizations in terms of the structural properties of the STN graph. This facilitates the potential application of the theory to other areas.

mathematical models