Closed Loop Control Compact Exercise Device for Use on MPCV

Abstract

Long duration space travel to Mars or to an asteroid will expose astronauts to extended periods of reduced gravity. To combat spaceflight physiological deconditioning, astronauts will use resistive and aerobic exercise regimens for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the mass and volume available for an exercise device in the next generation of spacecraft is limited. Therefore, compact exercise device prototypes are being developed for human in the loop evaluations. The NASA Human Research Program (HRP) is managing Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation for all exploration mission profiles from Multi-Purpose Crew Vehicle (MPCV) exploration missions (e.g., EM-2, up to 21 day) to Mars Transit (up to 1000 day) missions. Numerous technologies have been considered and evaluated against HRP-approved functional requirements and include flywheel, pneumatic and closed-loop microprocessor-controlled motor driven power plants. Motor driven technologies offer excellent torque density and load accuracy characteristics as well as the ability to create custom mechanical impedance (the dynamic relationship between force and velocity) and custom load versus position exercise algorithms. Further, closed-loop motor-driven technologies offer the ability to monitor exercise dose parameters and adapt to the needs of the crewmember for real time optimization of exercise prescriptions. A simple proportional-integral-derivative (PID) controller is demonstrated in a prototype motor driven exercise device with comparison to resistive static and dynamic load set points and aerobic work rate targets. The resistive load term in the algorithm includes a constant force component (Fcmg) as well as inertial component (Fima) and a discussion of system tuning is presented in terms of addressing key functional requirements and human interfaces. The device aerobic modality is modelled as a rowing exercise using ground data sets obtained from Concept 2 rowers as well as competitive rowing1. A discussion of software and electronic implementations are presented which demonstrate unique approaches to meeting the constrained mass, volume and power requirements of the MPCV. . In addition to utilizing traditional PID control, controllers utilizing state feedback with gains solved using a Linear Quadratic Regulator will be developed. Controllability and observability will be utilized to investigate the need for state measurement in the design. As the control system directly interacts with human test subjects, robust methods such as H-infinity are also being investigated.1. Kleshnev V. Biomechanics. In: Rowing, Handbook of Sports Medicine and Science. ed. by Secher N., Voliantis S. IOC Medical Commission, Blackwell Pub. pp. 22-34, 2007

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sheehan, Chris, Funk, Justin, Funk, Nathan, Kutnick, Gilead, Humphreys, Brad, Bruinsma, Douwe, Perusek, Gail. 2016-02-01. Closed Loop Control Compact Exercise Device for Use on MPCV. https://ntrs.nasa.gov/citations/20170009562

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The CapiSorb Visible System (CVS) Demonstrations on ISS

Falling liquid film amine sorbent reactors have been successfully employed to scrub CO 2 aboard submarines for decades. However, applying such proven methods aboard orbiting and coast spacecraft is significantly challenged by the nearly weightless environment, where liquid sprays and films do not fall, and vapor bubbles and gases do not rise. The Capillary Sorbent (CapiSorb) Visible System (CVS) is a technology demonstration experiment performed aboard the ISS April 18 – 21, 2023. The system establishes stable steady thin liquid film flows in Contactor (absorber) and Degasser (desorber/stripper) replacing the passive role of gravity with the combined passive roles of surface tension, wetting, and system geometry. A TOX-0 fructose ersatz liquid sorbent is employed enabling ‘transparent’ experiments performed and filmed by the crew safely in the open cabin of the ISS. Completed objectives include demonstrations of stable passive ‘massively’ parallel planar thin film capillary flows across atmospheric pressure Contactor and sealed heated Degasser. The impacts of varying flow rate, flow direction, heat input, viscosity, positive and negative Degasser pressures, condensate collection and return, fluid distribution, interfacial stability, and others are reported. At least 49 diagnostics are recorded for digitization and subsequent thermal-fluids model validation by a single HD video downlink during the nearly 22 hours of operations. An overview of the flight hardware including description of the components, diagnostics, crew procedures, flight operations, and summary of accomplishments is reported in Ref. 1. Further details of the diagnostics, tests performed, and data reduction is reported in Ref. 2. This report collects both1,2 into a single report adding methods of data digitization, reduction, and archive along with analyses and discussions of technology impacts.

microgravity

The Double-Drained Drop: Symmetric Draining of Liquids from Containers with Interior Corners

An analytic solution is found for the late stage draining of a wetting capillary liquid from an interior corner. The solution exploits the symmetry of volumetric sink conditions at opposing ends of such a `double-drained' interior corner flow with applications ranging from liquid recovery in microfluidic devices on earth to liquid fuels scavenging in large fuel tanks aboard spacecraft. At long times t, the liquid depth is h~t^n, the liquid volume is V~ t^(2n), and the maximum volumetric liquid removal rate is Q~t^(2n-1), where n =-1. Representative experiments are conducted at larger length scales aboard the International Space Station and at microfluidic length scales in a terrestrial laboratory. Both sets of experiments confirm the solutions. We show that the approach offers a method to predict maximum drain rates from related geometries where a single drain location provides the required symmetry. We also show that the `fixed length' solution is one of many practical similarity solutions to the governing nonlinear evolution equation for the transient liquid profile along the interior corner. Exponential asymptotic Fourier series solutions are also found for partial corner fillling as well as draining.

microgravity