In this paper, preliminary results for the recently-updated Open National Combustion Code (Open NCC) as applied to the EEE are presented. The comparison between two different numerical schemes, the standard Jameson-Schmidt-Turkel (JST) scheme and the advection upstream splitting method (AUSM), is performed for the cold flow and the reacting flow calculations using the RANS. In the cold flow calculation, the AUSM scheme predicts a much stronger reverse flow in the central recirculation zone. In the reacting flow calculation, we test two cases: gaseous fuel injection and liquid spray injection. In the gaseous fuel injection case, the overall flame structures of the two schemes are similar to one another, in the sense that the flame is attached to the main nozzle, but is detached from the pilot nozzle. However, in the exit temperature profile, the AUSM scheme shows a more uniform profile than that of the JST scheme, which is close to the experimental data. In the liquid spray injection case, we expect different flame structures in this scenario. We will give a brief discussion on how two numerical schemes predict the flame structures inside the EEE using different ways to introduce the fuel injection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Miki, Kenji, Moder, Jeff, Liou, Meng-Sing. 2016-11-20. Computational Flow Field in Energy Efficient Engine (EEE). https://ntrs.nasa.gov/citations/20170009579

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD