NASA NTRS · 20170010190
Development Specification for the Portable Life Support System (PLSS) Thermal Loop Pump
Abstract
The AEMU Thermal Loop Pump Development Specification establishes the requirements for design, performance, and testing of the Water Pump as part of the Thermal System of the Advanced Portable Life Support System (PLSS). It is envisioned that the Thermal Loop Pump is a positive displacement pump that provides a repeatable volume of flow against a given range of back-pressures provided by the various applications. The intention is to operate the pump at a fixed speed for the given application. The primary system is made up of two identical and redundant pumps of which only one is in operation at given time. The Auxiliary Loop Pump is an identical pump design to the primary pumps but is operated at half the flow rate. Inlet positive pressure to the pumps is provided by the upstream Flexible Supply Assembly (FSA-431 and FSA-531) which are physically located inside the suit volume and pressurized by suit pressure. An integrated relief valve, placed in parallel to the pump's inlet and outlet protects the pump and loop from over-pressurization. An integrated course filter is placed upstream of the pump's inlet to provide filtration and prevent potential debris from damaging the pump.
Keep this discovery
Explore connections, maps & timelines
Anchondo, Ian, Campbell, Colin. 2017-03-22. Development Specification for the Portable Life Support System (PLSS) Thermal Loop Pump. https://ntrs.nasa.gov/citations/20170010190
Cite the original work for its findings. Save a collection to share your selection of sources.