Search NASA⌕ Search

NASA NTRS · 20180006640

Free-Flight Trajectory Simulation of the ADEPT Sounding Rocket Test Using CFD

Abstract

A computational study of the Adaptive Deployable Entry and Placement Technology (ADEPT) Sounding Rocket (SR-1) Test is presented using the US3D flow solver. ADEPT SR-1 is intended, in part, to assess the dynamic stability of this entry vehicle architecture. Given that no dynamic stability data exists for the ADEPT geometry, a limited ballistic range campaign has been performed to characterize the vehicle's stability characteristics pre-flight for Mach numbers between 1.21 and 2.5. Here, this data is used to assess the accuracy of US3D's free-flight CFD capability. Computed trajectories from US3D and experimental data show that the flow solver compares well in vehicle oscillation frequency, downrange distance, and oscillatory amplitude during high Mach number flight (Mavg = 2.36). For Mach numbers below 1.5, the solver under predicts total angle-of-attack by an average of 16%, but compares well in oscillatory frequency and downrange distance. Additionally, a capability for simulating the trajectory of the flight article through the atmosphere using CFD is presented. This capability couples US3D's free-flight capability to an atmosphere model that accounts for changes in free-stream density and temperature as the vehicle descends. Two simulations for the purpose of demonstrating the capability and viability of this approach are applied to SR-1 flight article, and some unique challenges are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hergert, Jakob D., Brock, Joseph M., Stern, Eric C., Wilder, Michael C., Bogdanoff, David W.. 2017-06-05. Free-Flight Trajectory Simulation of the ADEPT Sounding Rocket Test Using CFD. https://ntrs.nasa.gov/citations/20180006640

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗