Search NASA⌕ Search

NASA NTRS · 20180007734

HgCdTe e-APD Detector Arrays with Single Photon Sensitivity for Space Lidar Applications

Abstract

A multi-element HgCdTe electron initiated avalanche photodiode (e-APD) array has been developed for space lidar applications. The detector array was fabricated with 4.3-μm cutoff HgCdTe which covered a spectral response from 0.4 to 4.3 μm. We have characterized a 4x4 detector array with 80 μm square elements and an integrated custom cryogenic silicon read-out integrated circuit (ROIC). The device operated at 77K inside a small closed-cycle Dewar. Measurements showed a unity gain quantum efficiency of about 90% at 1.55 μm. The bulk dark current of the HgCdTe e-APD at 77K was less than 50,000 input referred electrons/s at 12 V APD bias where the APD gain was 620 and the measured noise equivalent power (NEP) was 0.4 fW/Hz1/2. The electrical bandwidth of the ROIC was about 6 MHz, which was chosen to match the laser pulse width of our CO2 lidar. Even with the relatively low bandwidth, the high APD gain and low dark current enabled the device to detect single photon events. Because the APD was biased below the break-down voltage, the detector output was linear with the input optical signal and there was no dead-time and afterpulsing. A new series of HgCdTe e-APDs are being developed with a much wider bandwidth ROIC and higher gain HgCdTe e-APD array, which is expected to give a much better performance in linear mode photon counting applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sun, Xiaoli, Abshire, James B., Beck, Jeffrey D.. 2014-05-28. HgCdTe e-APD Detector Arrays with Single Photon Sensitivity for Space Lidar Applications. https://ntrs.nasa.gov/citations/20180007734

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Linear Mode HgCdTe Avalanche Photodiodes for Photon Counting Applications

An overview of recent improvements in the understanding and maturity of linear mode photon counting with HgCdTe electron-initiated avalanche photodiodes is presented. The first HgCdTe LMPC 2x8 format array fabricated in 2011 with 64 micron pitch was a remarkable success in terms of demonstrating a high single photon signal to noise ratio of 13.7 with an excess noise factor of 1.3-1.4, a 7 ns minimum time between events, and a broad spectral response extending from 0.4 micron to 4.2 micron. The main limitations were a greater than 10x higher false event rate than expected of greater than 1 MHz, a 5-7x lower than expected APD gain, and a photon detection efficiency of only 50% when greater than 60% was expected. This paper discusses the reasons behind these limitations and the implementation of their mitigations with new results.

HgCdTe↗

Update on Linear Mode Photon Counting with the HgCdTe Linear Mode Avalanche Photodiode

The behavior of the gain-voltage characteristic of the mid-wavelength infrared cutoff HgCdTe linear mode avalanche photodiode (e-APD) is discussed both experimentally and theoretically as a function of the width of the multiplication region. Data are shown that demonstrate a strong dependence of the gain at a given bias voltage on the width of the n− gain region. Geometrical and fundamental theoretical models are examined to explain this behavior. The geometrical model takes into account the gain-dependent optical fill factor of the cylindrical APD. The theoretical model is based on the ballistic ionization model being developed for the HgCdTe APD. It is concluded that the fundamental theoretical explanation is the dominant effect. A model is developed that combines both the geometrical and fundamental effects. The model also takes into account the effect of the varying multiplication width in the low bias region of the gain-voltage curve. It is concluded that the lower than expected gain seen in the first 2 × 8 HgCdTe linear mode photon counting APD arrays, and higher excess noise factor, was very likely due to the larger than typical multiplication region length in the photon counting APD pixel design. The implications of these effects on device photon counting performance are discussed.

HgCdTe↗