NASA NTRS · 20200000318
Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods
Abstract
The Mars Science Laboratory (MSL) was protected during entry into the Martian atmosphere by a thermal protection system that used NASA’s Phenolic Impregnated Carbon Ablator (PICA). The heat shield of the probe was instrumented with the Mars Entry Descent and Landing Instrument (MEDLI) suite of sensors. MEDLI Integrated Sensor Plugs (MISP) included thermocouples that measured in-depth temperatures at various locations on the heatshield. The flight data has been used as a benchmark for validating ablation codes within NASA. This work seeks to refine the estimate of the material properties for the MSL heat shield and the aerothermal environment during Mars entry using estimation methods in DAKOTA on the temperature data obtained from MEDLI.
Keep this discovery
Explore connections, maps & timelines
Thornton, John M., Meurisse, Jeremie B., Mansour, Nagi N.. 2019-09-16. Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods. https://ntrs.nasa.gov/citations/20200000318
Cite the original work for its findings. Save a collection to share your selection of sources.