NASA NTRS · 20200001449
RH1021BMH-10 Precision 10 V Reference Total Ionizing Dose Test Report
Abstract
The purpose of this test was to validate the Analog Devices (ADI) RH1021BMH-10 flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for this flight lot with wafer lot number 769658.1 and lot date code (LDC) 1430A. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.
Keep this discovery
Explore connections, maps & timelines
Casey, Megan, Topper, Alyson, Phan, Anthony M.. 2020-01-01. RH1021BMH-10 Precision 10 V Reference Total Ionizing Dose Test Report. https://ntrs.nasa.gov/citations/20200001449
Cite the original work for its findings. Save a collection to share your selection of sources.