Abstract

The purpose of this test was to characterize the Micron 512 GB NAND (MT29F512G08AUCBBH8-6IT:B) flash memory parameter degradation for total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device parameters such as leakage currents, quantity of upset bits and overall chip and die health were investigated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alyson Dyan Topper, Edward Wilcox, Michael Campola. 2018-05-25. MT29F512G08AUCBBH8-6IT:B NAND Flash Memory Total Ionizing Dose Test Report. https://ntrs.nasa.gov/citations/20205006472

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

PE99155 Point-Of-Load Buck Regulator Total Ionizing Dose Test Report

Teledyne’s PE99155 point-of-load buck regulator was tested to evaluate an applicationspecific question about the start-up behavior of the device. This test determined if accumulated total ionizing dose (TID) affected any start-up voltage transient characteristics. Testing was based on pass/fail criterial for the magnitude of the output voltage to ensure the safety of downstream electronics. Two sets of radiation tests were performed. The first group of PE99155s used a high dose rate (HDR) irradiation to 25 krad(Si). A second group of PE99155s used high dose rate irradiation to 30 krad(Si).

TID↗