AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report
Abstract
The purpose of this testing was to characterize Analog Devices’ AD8065 FastFET amplifier for low-dose rate (LDR) total ionizing dose (TID) response based on the Lucy project requirements and will be used on the L’ORRI instrument being built by Johns Hopkins University Applied Physics Lab. The AD8065 is a voltage feedback amplifier with FET inputs developed with the proprietary eXtra Fast Complementary Bipolar (XFCB) process. The amplifier boasts low noise operation and very high input impedance with a wide supply voltage range.
Keep this discovery
Explore connections, maps & timelines
Megan Casey, Anthony Phan. 2020-03-19. AD8065 Voltage Feedback Amplifier’s Total Ionizing Dose Characterization Report. https://ntrs.nasa.gov/citations/20205007650