Abstract

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jennifer Eigenbrode, Robert E Gold. CONTAMINATION CONTROL FOR ULTRA-SENSITIVE LIFE DETECTION SCIENCE MISSIONS. https://ntrs.nasa.gov/citations/20205008716

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Effect of dimethyl phthalate contamination on all-silica GLAD quarter-wave plate performances

Phthalate molecular contamination, identified in the Laser Mégajoule target chamber, can severely alter porous coatings' performance, such as glancing angle deposited quarter-wave plates (QWP). QWPs could potentially be used inside this chamber to smooth the intensity of the focal spots on the target. In this study, all-silica QWP coatings were contaminated with dimethyl phthalate. Transmission was lowered due to the absorption of phthalates, and a non-uniform retardance was induced, even after a two-month storage period in air following contamination. Infrared measurements confirmed the presence of bonds associated with phthalates within the coatings due to their sorption and only partial desorption.

Contamination↗

Searching for Life on Mars: The Contamination Paradox

As we search for life on Mars, we will be simultaneously contaminating Mars with life from Earth. The contamination from Earth could be mistaken for Martian life. How can this paradox be avoided? With the results of our research, the scientific community will be able to determine locations of future habitats that minimize the aerial extent subject to bio-contaminants, protect sites of astrobiological interest, and constrain landing site selection of life detection missions to reduce risk of false positives. We consider a putative human habitat on Mars. Biological contaminants will flow out of the habitat into the Martian atmosphere, and the atmosphere will move these contaminants around. How many biological particles per year will be released from the habitat into the Martian ambient environment? How far will the contamination travel? In what directions will it travel? How long will the contamination be in the atmosphere? We study these questions quantitatively by simulating the Martian atmosphere using the NASA Ames Mars Global Climate Model. Various combinations of human habitat locations and contaminant sizes are considered. The results from these simulations enable the creation of novel contamination heat maps showing the aerial distribution of contaminants from putative human habitats on Mars.

Contamination↗

Study of Fallout Metrics for Contamination Analysis

A challenge present in assessing contamination accumulation on many missions is predicting fallout during ground processing given the multiple and various orientations possible for surfaces such as optics and instruments. The best practice assumption has been to quantify particle build up on vertical surfaces as approximately 1/10 that of horizontal surfaces. This fractional relation is important when considering contamination allocations necessary to meet cleanliness requirements since spacecraft can be in many orientations during integration and testing. There is insufficient data to provide confidence in the 1/10 approximation, yet its use can have a significant effect on mission end of life contamination level predictions, leading to expenditures of precious resources to meet mission requirements. A study was conducted to compare and analyze the fallout in horizontal and vertical orientations. Silicon wafers were deployed in four different facilities. Data sets from a long term deployment of wafers were analyzed from a cleanroom facility housing integration of the James Webb Space Telescope (JWST) as well as from a shorter term deployment of wafers in three cleanroom facilities at Goddard Space Flight Center with lower activity. There are many variables influencing the relationship between fallout on vertical and horizontal wafers, including wafer position with respect to air flow, air changes in the facility, duration of exposure, and activity workload. The goal of this continuing study is to develop a tool to inform particulate accumulation predictions for future projects.

Contamination↗