Search NASA⌕ Search

NASA NTRS · 20210003854

Surface Plasmon Tunable Filter and Spectrometer-on-a-Chip

Abstract

UNKNOWN

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wang, Y.. 1997-07-27. Surface Plasmon Tunable Filter and Spectrometer-on-a-Chip. https://ntrs.nasa.gov/citations/20210003854

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer↗

In-Flight Calibration and Performance of the OSIRIS-REx Visible and IR Spectrometer (OVIRS)

Performance of the Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) Visible and InfraRed Spectrometer (OVIRS) instrument was validated, showing that it met all science requirements during extensive thermal vacuum ground testing. Preliminary instrument radiometric calibration coefficients and wavelength mapping were also determined before instrument delivery and launch using NIST-traceable sources. One year after launch, Earth flyby data were used to refine the wavelength map by comparing OVIRS spectra with atmospheric models. Near-simultaneous data from other Earth-orbiting satellites were used to cross-calibrate the OVIRS absolute radiometric response, particularly at visible wavelengths. Trending data from internal calibration sources and the Sun show that instrument radiometric performance has been stable to better than 1% in the 18 months since launch.

spectrometer↗

Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer

Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.

spectrometer↗