FEA-Based Failure Analysis of Post-Buckled Composite Multi-Hat Stiffened Panel Under Static Compression

Abstract

The aerospace industry uses composite multi-hat stiffened panels for skins because of their high strength-to-weight and stiffness-to-weight ratios. However, laminated composites with initial flaws are susceptible to delamination under buckling loads. The goal is to ensure damage initiation occurs past the buckled state, only stable damage progression at loads below the ultimate compressive load, and debonding failure past the ultimate compressive load. This approach reduces weight and addresses a potential design review for future aircraft repairs. The need exists to better understand damage initiation and growth mechanisms in composite structures while assisting in the design, analysis, and sustainment methods. Teflon inserts simulate damage defects during manufacturing, while barely visible impact helps capture human error during manufacturing. This work shows the interaction between the skin-stringer and ply-ply separations at the post-buckled state for both defect events using Abaqus Virtual Crack Closure Technique (VCCT). The initial configuration for the Teflon case was to leave the Teflon region unbonded, and the initial impact damage region approximation came from the experimental data and was considered the initial configuration. When compared against the experimental data produced through the NASA Advanced Composites Project (ACP), the present model captured damage transition from skin-hat to ply1-ply2. The model validations were within ~5% of the experimental data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vijay K. Goyal, Austin Pennington. FEA-Based Failure Analysis of Post-Buckled Composite Multi-Hat Stiffened Panel Under Static Compression. https://ntrs.nasa.gov/citations/20220007502

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Understanding surfaces and interfaces in nanocomposites of silicone and barium titanate through experiments and modeling

Barium titanate (BTO) is a ferroelectric perovskite used in electronics and energy storage systems because of its high dielectric constant. Decreasing the BTO particle size was shown to increase the dielectric constant of the perovskite, which is an intriguing but contested result. We investigated this result by fabricating silicone-matrix nanocomposite specimens containing BTO particles of decreasing diameter. Furthermore, density functional theory modeling was used to understand the interactions at the BTO particle surface. Combining results from experiments and modeling indicated that polymer type, particle surface interactions, and particle surface structure can influence the dielectric properties of polymer-matrix nanocomposites containing BTO.

composite↗

Thermal Conductivity of 3D Woven Composite Thermal Protection System Materials via Multiscale Recursive Micromechanics

Multiscale micromechanics predictions have been made for the effective thermal conductivities and local thermal fields for a novel 3D woven composite thermal protection system material. The Multiscale Recursive Micromechanics approach, which enables micromechanics models to call other micromechanics models (or themselves recursively) to consider finer and finer length scales, has been employed. The multiscale model uses a recently developed version of the High-Fidelity Generalized Method of Cells micromechanics theory at each of three length scales. Results focus on the impact of the microstructural geometry representation at each length scale on the material’s effective thermal conductivity, along with the local thermal flux and temperature fields induced in the microstructures.

composite↗

Through-Thickness Tensile Properties of Triaxial Braided Composites

The through-thickness strength of triaxial braided composites was measured using thin specimens bonded to metallic tabs. Despite providing reasonable engineering estimates of the bulk properties, some test specimen limitations were noted: For strong epoxies, significant shear and tensile stresses occur and induce failure between the first layer and bond-line; the strains over much of the exterior are ~10% lower than interior strains, which are representative of the nominal state; and failure often occurred near or along the adhesive bond line. These interference were partially overcome by adding a large radius to the gage section. Based on the finite element analysis and experimental measurements, the nominal elastic modulus and Poisson's ratio are E(sub 33) = 10.7 GPa and v(sub 31) = 0.08 for the three triaxial braided composites tested. Strengths vary from 14 to 40 MPa depending on the resin. Relative to the in-plane properties, the through thickness modulus, fracture strength, failure strain, and Poisson's ratio are 1/5th, 1/30th, 1/6th, and 1/4th. Interlaminar failure occurred with varying degrees of fiber tear out along with little damage to axial tows, resulting is a smooth undulating fracture surface. Post cure temperature excursions to 177 deg C (350 deg F) had little effect on elastic constants but reduced the strength E862 based composites severely. The strength of PR520 and 5208 based composites increased.

composite↗